ABB AC800F MANUAL PDF

AC M controller A Programmable Automation Controller, designed to achieve high availability for control applications in the process industry The rich function block library includes several types of control loops, including advanced control and auto- tune capabilities as well as integration for ABB drives and motors. The controller communication by means of Ethernet includes on board RNRP redundancy along with a broad set of communication modules to connect to third-party devices. A superior redundancy concept allows for fast switch-over times and topologically separated CPU-modules. Several CPU modules are available, varying in terms of processing power, memory size and redundancy support.

Author:Gubei Moogulmaran
Country:Martinique
Language:English (Spanish)
Genre:Video
Published (Last):9 August 2012
Pages:310
PDF File Size:13.30 Mb
ePub File Size:10.10 Mb
ISBN:714-3-29385-442-7
Downloads:42617
Price:Free* [*Free Regsitration Required]
Uploader:Dagrel



The selection list of the redundant AC F only offers modules marked with an R at the end, e. FI FR. The R stands for redundancy-capable and simply means that the parameter dialog differs slightly from the non-redundancy-capable object.

Insertion of the modules is only possible in the upper basic unit. The station must be allocated to a resource D-PS. This defines which software part of the user program runs on which process station. The AC F has 4 Mbytes memory. The memory is subdivided into differ- ent parts as listed below. Not redundant As of version 6. Page Ac f Modules F power supply module for 24 V DC and redundant power supply, which meets stricter re- quirements for the availability of the power supply.

For further parameter information and object data, see Parameterization of AC F, page 20 and Diagnostic data for objects, page For each FieldController, it is possible to connect only one station bus CAN line with maximum 5 racks. The errors are saved bit-coded in the error code. The following are A toggle is possible only in SYNC status.

The FieldController is loaded with the operating system and is initialized. The redundancy is now no longer ac- tive. A cold start task -is per- formed once.

All lower-level program lists and programs start along with the task as long as the program list parameter has been set ON.